SafeFlo®
Overview
Features & Benefits
SPACE STATION®
VascuGrasp®



To View Implantation Clip


To View SafeFlo® Brochure
PDF File


For information regarding clinical, distribution or partnership opportunities for SafeFlo® please contact Rafael Medical.


Overview

Rafael Medical's initial device is SafeFlo®, a retrievable (or optional) vena cava filter for the management and prevention of Pulmonary Embolism, a condition that has been estimated to cost the U.S. healthcare system over $1.5 billion annually.

SafeFlo® utilizes shape memory alloys and is based on a highly innovative spiral design that employs the company's SPACE STATION® intravascular platform for its fixation within the vessel.


View our SafeFlo® demo

Low Bandwidth (190KB)
High Bandwidth (980KB)

SafeFlo® is unique in that it provides an alternative anchoring mechanism to the standard linear "legs and hooks" or "box and hooks" designs of existing filters currently available on the market.

Features & Benefits

The SafeFlo® Vena Cava Filter offers two-levels of anchoring with a platform that oversizes the vessel preventing migration while maintaining vessel integrity1. A 5-petalled flower loop configuration provides highly effective clot capture of clinically significant clots2. The configuration is designed to sit centrally in the lumen minimizing impedance to flow with a low incidence of thrombosis3.

The SafeFlo® filter offers the following advantages:


Versatility and Control The SafeFlo® filter can be fully deployed and then collapsed back into its delivery sheath and redeployed in a different position from both the femoral and jugular approaches prior to active detachment from the delivery system. This minimizes the disadvantages and risks associated with imperfect filter positioning.
Vessel Friendly The SafeFlo® filter's fixation is by diffuse pressure on the full circumference of the vessel wall provided by the rings of the anchoring platform.
Sizing The SafeFlo® filter is offered in three sizes (Small, Medium, Large) covering a range of vessel diameters between 15mm and 27mm allowing for vessel-compatible anchoring. All sizes can be deployed from the jugular or femoral approaches using a low profile 6F delivery system.

1 Bench testing, animal and clinical study data on file.
2 Bruckheimer E. et al. In vitro evaluation of a retrievable low-profile nitinol vena cava filter. JVasc Interv Radiol 2003 14: 469-474.
3 Animal and clinical study data on file.







SafeFlo® is CE Marked and approved for sale in the European Community.

Caution: Federal (U.S.) Law restricts SafeFlo® for investigational use only.